Skip to main content

Daily ReportNov 16, 2026

Anesthesiology, November 16 edition

We read 50 papers and selected 3.

Summary

Today’s most impactful anesthesiology research includes a prospective study establishing age-specific electroencephalography spectral edge frequency 95 targets for propofol anesthesia in toddlers, a systematic review showing opioid-sparing advantages of quadratus lumborum block over transversus abdominis plane block, and a comparative study demonstrating superior accuracy and reliability of electromyography-based neuromuscular monitoring when thumb movement is restricted. Together, these studies address pediatric anesthetic titration, multimodal analgesia, and prevention of residual neuromuscular blockade.

Research Themes

  • Pediatric EEG-guided anesthetic titration
  • Opioid-sparing regional anesthesia
  • Quantitative neuromuscular monitoring

Selected Articles

1. Electroencephalography-derived spectral edge frequency 95 targets in toddlers under propofol anaesthesia✰.

80.0Evidence level IIICohort
British journal of anaesthesia2026PMID: 43039805

This prospective study of 51 toddlers aged 13–24 months established SEF95 thresholds associated with nonresponse to consciousness, nociceptive, and laryngoscopy stimuli during propofol anesthesia. ED90 values were 20.3 Hz for pacifier placement, 10.4 Hz for electrical stimulation, and 4.4 Hz for laryngoscopy; each 1-Hz increase in SEF95 corresponded to a 0.21 μg/mL lower plasma propofol concentration.

Impact: Processed EEG indices are often unreliable in very young children, creating a major gap in individualized anesthetic titration. This study provides stimulus-specific, age-relevant SEF95 targets that could improve EEG-guided propofol dosing in toddlers.

Clinical Implications: SEF95 may be incorporated into EEG-guided propofol titration for children younger than 2 years, with different targets for consciousness, nociception, and intubation readiness. The thresholds should be externally validated before being used as universal dosing targets.

Key Findings

  • In 51 toddlers, SEF95 ED90 targets were 20.3 Hz for pacifier placement, 10.4 Hz for electrical stimulation, and 4.4 Hz for laryngoscopy.
  • SEF95 was inversely associated with plasma propofol concentration; each 1-Hz increase corresponded to a 0.21 μg/mL decrease.
  • The study generated age-specific targets for three clinically distinct anesthetic stimuli in children aged 13–24 months.

Methodological Strengths

  • Prospective clinical design with a registered clinical trial protocol.
  • Use of Dixon’s up-and-down method, centred isotonic regression, and mixed-effects modeling for clinically relevant threshold estimation.

Limitations

  • The sample size was modest and limited to toddlers aged 13–24 months.
  • The study established physiological and behavioral thresholds but did not demonstrate improved clinical outcomes or reduced adverse events.

Future Directions: Multicenter studies should validate these thresholds across different anesthetic regimens, neurologic states, and monitoring systems, and should determine whether SEF95-guided dosing reduces excessive anesthesia, hemodynamic instability, or recovery time.

BACKGROUND: Proprietary processed EEG indices are less accurate in young children. We evaluated spectral edge frequency 95 (SEF95), a nonproprietary EEG index representing the frequency below which 95% of total EEG power resides, to establish target thresholds for varying anaesthetic depths during propofol anaesthesia in toddlers. Secondary objectives were to assess the relationship between SEF95 and plasma propofol concentration, and to evaluate airway reactivity during laryngoscopy. METHODS: In this prospective study of toddlers aged 13 to 24 months, Dixon's up-and-down method and centred isotonic regression were used to determine the SEF95 targets for 50% (ED50) and 90% (ED90) probability of nonresponse to three clinical stimuli: pacifier placement (assessing consciousness), electrical nerve stimulation (nociception), and laryngoscopy (intubation readiness). Linear mixed-effects regression was used to analyse the association between plasma propofol concentration and SEF95. RESULTS: Among 51 toddlers, SEF95 ED50 and ED90 targets (Hz) were 21.8 (90% CI 20.8-23.4) and 20.3 (19.1-20.7) Hz for pacifier placement, 12.0 (10.8-18.3) and 10.4 (8.7-11.3) Hz for electrical stimulation, and 10.3 (4.6-11.8) and 4.4 (1.5-5.4) Hz for laryngoscopy.

2. Quadratus lumborum versus transversus abdominis plane block for postoperative analgesia in laparoscopic colorectal surgery: a systematic review and meta-analysis of randomized controlled trials.

72.5Evidence level ISystematic Review and Meta-analysis
Techniques in coloproctology2026PMID: 43035539

This systematic review and meta-analysis included four randomized trials involving 419 patients undergoing laparoscopic colorectal surgery. Compared with TAP block, quadratus lumborum block reduced 24-hour opioid consumption by 8.92 mg morphine equivalents and modestly reduced pain at rest and during movement, without significantly increasing postoperative nausea, vomiting, or dizziness.

Impact: The analysis directly compares two commonly used regional analgesic techniques within enhanced recovery pathways and quantifies an opioid-sparing benefit. It also appropriately highlights uncertainty caused by heterogeneity and limited trial numbers.

Clinical Implications: Quadratus lumborum block can be considered an opioid-sparing component of multimodal analgesia after laparoscopic colorectal surgery, but routine preference over TAP block should await larger, standardized multicenter trials.

Key Findings

  • Four randomized controlled trials with 419 patients were included.
  • Quadratus lumborum block reduced 24-hour opioid consumption by 8.92 mg morphine equivalents compared with TAP block.
  • Pain scores were lower with quadratus lumborum block at rest and during movement, without significant differences in postoperative nausea, vomiting, or dizziness.

Methodological Strengths

  • Systematic search across four major databases with independent screening and data extraction.
  • Use of Cochrane Risk of Bias 2 and GRADE to distinguish pooled effects from certainty of evidence.

Limitations

  • Only four randomized trials were available, limiting statistical power and generalizability.
  • Substantial heterogeneity was present for opioid consumption and pain during movement, and prediction intervals included clinically uncertain effects for some outcomes.

Future Directions: Future multicenter trials should standardize block technique, local anesthetic dose, surgical approach, background analgesia, and outcome definitions, while examining recovery quality, opioid-related adverse events, and cost-effectiveness.

BACKGROUND: Effective pain management after surgery is crucial for recovery following laparoscopic colorectal resection in enhanced recovery after surgery (ERAS) programs. While the transversus abdominis plane (TAP) block is commonly used, it may not fully address visceral pain. The quadratus lumborum (QL) block might provide better coverage for both somatic and visceral pain due to its ability to spread to the thoracolumbar fascia and paravertebral space. OBJECTIVES: This study aims to compare the clinical outcomes of QL versus TAP blocks in laparoscopic colorectal surgery. The main outcome was total opioid use within 24 h. Secondary outcomes included early pain scores, time until the first rescue analgesic was needed, postoperative nausea and vomiting (PONV), length of stay, surgical complications, and side effects related to the blocks. METHODS: We conducted a systematic literature search using PubMed, Cochrane CENTRAL, Web of Science Core Collection, and Scopus from database inception to 27 July 2025 for randomized controlled trials (RCTs) comparing QL and TAP blocks. Two reviewers independently screened the studies, extracted data, and assessed quality using the Cochrane Risk of Bias 2 tool. We calculated pooled estimates using a random-effects model and evaluated the reliability of the evidence on the basis of the grading of recommendations, assessment, development, and evaluation (GRADE) framework. RESULTS: Four RCTs (n = 419) met the inclusion criteria. Compared with the TAP block, the QL block led to lower opioid use within 24 h (MD [mean difference] -8.92 mg morphine equivalents; 95% CI -11.57 to -6.28) and reduced pain scores both at rest MD -0.25 (-0.37 to -0.21) and during movement MD -0.40 [-0.52 to -0.29].

3. Accuracy and Precision of Acceleromyography and Electromyography at the Adductor Pollicis Muscle in Restricted Thumb Movement Positions: An Observational Study.

71.5Evidence level IIICohort
Anaesthesia, critical care & pain medicine2026PMID: 43039074

In 40 patients, 3,733 train-of-four measurements were obtained while both arms were immobilized under surgical drapes. Electromyography was more accurate and precise than acceleromyography, with a coefficient of repeatability of 0.10 versus 0.35 and a substantially lower measurement failure rate of 3.6% versus 27.7%; acceleromyography failures increased after approximately 45 minutes.

Impact: Residual neuromuscular blockade can be missed when acceleromyography is technically compromised by restricted thumb movement. This study provides direct quantitative evidence supporting electromyography in common surgical positions where conventional AMG assumptions are not met.

Clinical Implications: Electromyography-based quantitative neuromuscular monitoring should be considered when the thumb cannot move freely, particularly when arms are tucked or otherwise immobilized. Reliance on failed or unstable AMG readings may impair safe extubation decisions.

Key Findings

  • Among 40 patients, EMG had better accuracy and precision than AMG during restricted thumb movement.
  • The coefficient of repeatability was 0.10 for EMG versus 0.35 for AMG.
  • Measurement failure was substantially lower with EMG than AMG, at 3.6% versus 27.7%, respectively.

Methodological Strengths

  • Prospective simultaneous comparison of EMG and AMG on contralateral arms under realistic surgical positioning.
  • Large number of repeated train-of-four measurements with prespecified accuracy, precision, and failure metrics.

Limitations

  • Participants did not receive neuromuscular blocking drugs, so performance during clinically relevant residual blockade was not directly tested.
  • The study used one positioning and monitoring context, which may limit generalizability to other devices, muscles, or surgical setups.

Future Directions: Randomized clinical studies should compare EMG and AMG during neuromuscular blockade and reversal, assess postoperative respiratory outcomes, and evaluate whether EMG-based monitoring reduces unplanned reintubation or residual paralysis in high-risk surgical populations.

BACKGROUND: Quantitative neuromuscular monitoring commonly uses acceleromyography (AMG) or electromyography (EMG). Acceleromyography requires unrestricted thumb movement, whereas EMG is independent of thumb motion. We compared the accuracy and precision of AMG and EMG responses after patients' arms were immobilized during routine surgical positioning. METHODS: Patients undergoing general anaesthesia without neuromuscular block were enrolled. EMG and AMG monitors were placed on contralateral arms, and both arms were tucked under surgical drapes. The monitors simultaneously recorded train-of-four ratio (TOFR) after ulnar nerve stimulation every minute. Accuracy was defined as TOFR variability from the expected baseline value (1.00), and precision as consistency of repeated measurements, quantified by the coefficient of repeatability (CR). Failed measurements were defined as the absence of valid quantitative TOFR values, displayed as "0" or "?". AMG TOFR values were normalized to patient-specific baseline TOFR measurements for secondary analyses. RESULTS: Forty patients provided 3,733 TOFR measurements (1,879 EMG and 1,854 AMG). EMG was more accurate than AMG (mean EMG-AMG difference in absolute deviation from 1.0, -0.108; 95% confidence interval [CI], -0.134 to -0.083; p <  0.001) and more precise, with a smaller CR (0.10 vs. 0.35; p <  0.001), including compared with normalized AMG (CR, 0.35). Device failure rate was lower with EMG than AMG (3.6% vs. 27.7%; p =  0.0003). Failures increased over time, particularly for AMG after approximately 45 minutes.